On this page
- What is the standard size of a parking space?
- Parking space dimensions by angle
- Compact stalls and vehicle overhang
- What are 45 degree parking space dimensions?
- ADA parking space dimensions owners must meet
- Why are parking spaces still so narrow?
- Worked example: widening stalls from 8.5 to 9 feet
- How Wins Parking handles stall layout and restriping
- Next step
A standard 90-degree parking space is about 9 feet wide and 18 to 20 feet long. Many city codes use 9 feet by 20 feet with a 24-foot two-way aisle. Federal ADA rules add a 96-inch minimum for accessible car spaces, plus a 60-inch access aisle beside each one.
Local zoning sets the exact numbers. Check your city code before you design or restripe. The figures below come from published code and the U.S. Access Board.
What is the standard size of a parking space?
There is no single national stall size. Each city writes its own. Most land near the same range:
- Width: 9 feet is the common minimum for a full-size stall.
- Length (depth): 18 to 20 feet for a 90-degree stall.
- Two-way aisle: 24 feet behind 90-degree stalls.
Forest Lake, Minnesota is a typical example. Its zoning code sets every stall at 9 feet wide by 20 feet long. It requires a 24-foot aisle for 90-degree parking and for any two-way aisle. (Forest Lake parking dimensions)
Compact stalls are smaller. Raleigh, North Carolina lets compact spaces shrink to 7.5 feet wide by 15 feet long. Each one must be striped and labeled for compact cars only. (Raleigh UDO Sec. 7.1.6)
Parking space dimensions by angle
The stall angle changes how wide the aisle must be. Steeper angles need wider aisles because drivers turn more sharply to enter.
| Angle | Stall width | Stall length | One-way aisle | Two-way aisle |
|---|---|---|---|---|
| 0° (parallel) | 9 ft | 20 ft | 12 ft | 24 ft |
| 30° | 9 ft | 20 ft | 12 ft | 24 ft |
| 45° | 9 ft | 20 ft | 13 ft | 24 ft |
| 60° | 9 ft | 20 ft | 18 ft | 24 ft |
| 90° | 9 ft | 20 ft | 24 ft | 24 ft |
Source: Forest Lake, Minnesota zoning code. Your city may differ by a foot or more.
Angled parking has two practical benefits. It allows one-way aisles. It also makes stalls easier to enter for large pickups and SUVs. The tradeoff is fewer stalls per foot of curb.
Compact stalls and vehicle overhang
Compact stalls save space, but codes cap them. Auburn, Washington allows compact spaces up to 30% of a lot's total. Each one must be marked "COMPACT" on the pavement or on a sign. (Auburn City Code 18.52.050)
Auburn also allows up to 2 feet of vehicle overhang past the curb. The overhang cannot shrink a sidewalk below 4 feet of clear width. Owners can use this rule to shorten stall depth where a landscape strip or wide walk sits at the head of the stall.
Mark compact stalls in the far rows. Put full-size and accessible stalls near the entrance, where turnover is highest.
What are 45 degree parking space dimensions?
Under the Forest Lake table, a 45-degree stall is 9 feet wide and 20 feet long. It needs only a 13-foot one-way aisle. A 90-degree layout needs 24 feet.
That 11-foot difference matters on narrow sites. A long, thin lot often fits more cars with one-way angled rows than with two-way 90-degree rows. Angled rows also force one direction of travel. That reduces head-on conflicts in the aisle.
Two cautions apply. Angled stalls take more curb length per car because each stall sits on a diagonal. And one-way aisles need clear arrows and signs, or drivers will go the wrong way.
ADA parking space dimensions owners must meet
Accessible spaces follow the 2010 ADA Standards. These are federal rules, not local options. The U.S. Access Board guide sets these minimums: (Access Board parking guide)
- Car space: 96 inches (8 feet) wide, marked to show that width.
- Access aisle: 60 inches (5 feet) wide, at least as long as the space.
- Van space: 132 inches wide with a 60-inch aisle, or 96 inches wide with a 96-inch aisle.
- Van clearance: 98 inches of vertical clearance at van spaces, aisles and the route to them.
- Slope: no steeper than 1:48 in any direction on the space or aisle.
The count also follows a federal table. A 1–25 space lot needs 1 accessible space. A 26–50 space lot needs 2. A 51–75 space lot needs 3. A 76–100 space lot needs 4. At least 1 of every 6 accessible spaces must be van-accessible.
Wins Parking: under the 2010 ADA Standards, a 60-space lot needs 3 accessible spaces, and at least 1 of them must be van-accessible (November 2026).
Why are parking spaces still so narrow?
Most codes were written decades ago. Vehicles kept growing. Stall widths did not.
Europe tracks this closely. Transport & Environment found new cars in Europe grew from 177.8 cm wide to 180.3 cm in the first half of 2023. That is about 1 cm every two years. (Transport & Environment)
Codes set minimums, not targets. Nothing stops an owner from striping wider than the minimum. The cost is fewer stalls. The gain is fewer door dings, fewer complaints and faster turnover.
Worked example: widening stalls from 8.5 to 9 feet
Take a 60-space office lot. It has two rows of 30 stalls at 8.5 feet each. Each row runs 255 feet.
Restripe at 9 feet and the same 255 feet holds 28 stalls (255 ÷ 9 = 28.3). Each row loses 2 stalls. The lot drops from 60 to 56 spaces, a 6.7% loss.
Run three checks before you commit:
- Code minimums. Confirm your city's required space count. The lot cannot fall below it.
- ADA count. At 56 spaces the lot still needs 3 accessible spaces. The count holds from 51 to 75.
- Peak demand. Count cars at your busiest hour. If peak is 50 cars, 56 wider stalls serve tenants better than 60 tight ones.
A mixed plan also works. Stripe the rows nearest the door at 9.5 or 10 feet for trucks and vans. Keep the far rows at code minimum.
How Wins Parking handles stall layout and restriping
Wins Parking designs, builds and manages parking lots and garages. Our team handles the full layout job:
- Code check. We pull your local stall, aisle and accessible-space rules before drawing.
- Layout design. We test 90-degree and angled options and show the stall count for each.
- ADA compliance. We place accessible and van spaces on the shortest route to the entrance, inside the 1:48 slope limit.
- Striping and paving. Wins Design & Build handles grading, paving, drainage and striping.
- Management. We run permits, LPR cameras, payment and enforcement after the paint dries.
See our parking management services and completed work on our case studies page. For winter sites, read our guide to snow storage design for parking lots. If you are planning a new lot, our post on how many spaces to build covers sizing.
Next step
Send us your site plan or a photo of your lot. We will return a stall count for each layout option and an ADA check. Call (970) 279-1744 or start at https://winsparking.com/contact.
Frequently asked questions
What is the typical size of a parking space?
A typical parking space in the United States is 9 feet wide and 18 to 20 feet long for 90-degree parking. Forest Lake, Minnesota, for example, requires 9 by 20 feet with a 24-foot two-way aisle. Each city sets its own minimum, so confirm your local zoning code before you design or restripe a lot.
What is the ideal size for a parking space?
The ideal parking space size depends on who parks there. Code minimums near 9 feet wide suit sedans. Lots serving pickups, vans and contractor trucks work better with 9.5 to 10 foot stalls near the entrance. Wider stalls cut door damage and complaints but reduce total spaces, so test the stall count before restriping.
How wide is an ADA van-accessible parking space?
Under the 2010 ADA Standards, a van-accessible parking space is either 132 inches wide with a 60-inch access aisle, or 96 inches wide with a 96-inch access aisle. Van spaces, their aisles and the route to them also need 98 inches of vertical clearance. At least 1 of every 6 accessible spaces must be van-accessible.
How many accessible parking spaces does a lot need?
The 2010 ADA Standards set the count by lot size. A lot with 1 to 25 spaces needs 1 accessible space. A lot with 26 to 50 needs 2, 51 to 75 needs 3, and 76 to 100 needs 4. At least 1 of every 6 accessible spaces must be van-accessible. Restriping does not remove this requirement.
Can I make my parking spaces wider than the code minimum?
Yes. Zoning codes set minimum stall widths, not maximums, so owners can stripe wider stalls. The limit is the required space count. In a 255-foot row, moving from 8.5-foot to 9-foot stalls drops capacity from 30 to 28 spaces. Confirm the new total still meets your city's parking requirement and the ADA accessible-space count.